Volume 8, Issue 4 (12-2018)                   J Health Saf Work 2018, 8(4): 371-382 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moradirad R, Haghighat M, Yazdanirad S, Hajizadeh R, Shabgard Z, Mousavi S M. Selection of the most suitable sound control method using fuzzy hierarchical technique . J Health Saf Work 2018; 8 (4) :371-382
URL: http://jhsw.tums.ac.ir/article-1-5960-en.html
1- M.Sc., Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2- Instructor, Department of Occupational Health Engineering, Behbahan Faculty of Medical Sciences, Behbahan, Iran
3- M.Sc., Department of Occupational Health Engineering, Faculty of Health and Paramedical Sciences, Zanjan University of Medical Sciences, Zanjan, Iran
4- B.Sc., Department of Occupational Health Engineering, Faculty of Health, Ahvaz Joundishapur University of Medical Sciences, Ahvaz, Iran
5- M.Sc., Department of Occupational Health Engineering, Faculty of Health, Tehran University of Medical Sciences,Tehran, Iran , mahdi.mousavi90@yahoo.com
Abstract:   (4487 Views)
Introduction: Noise is one of the most harmful industrial agents and there are different methods to control it. Fuzzy analytical hierarchy process is an appropriate technique for selecting the best choice among several control methods. Therefore, the aim of this study was the selection of the most suitable sound control method using fuzzy hierarchical analysis (FAHP) technique in a refinery plant.
Material and Method: The present study was a cross-sectional research in a refinery plant. After identifying the main sources of the noise in the studied palnt, five criteria and ten noise control methods were selected using a questionnaire and Delphi methods. Then, Fuzzy hierarchy analysis was applied for the selection of the best noise control alternative.
Result: The results showed that the performance with a final weight of 0.277 and the non-interference in the process with a final weight of 0.06 were most and least important criteria, respectively. Meanwhile, worker enclosure had highest score (0.207) of the control methods.
Conclusion: In general, the results showed that best criterion for selection of the suitable noise control method is performance. What’s more, based on the results, worker enclosure was selected as best noise control method in the refinery.
Full-Text [PDF 685 kb]   (3071 Downloads)    
Type of Study: Research |
Received: 2018/12/7 | Accepted: 2018/12/7 | Published: 2018/12/7

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb