Monazzam Esmaielpour M R, Laal F, Majlessi F, Fallah Madvari R, Rahimi Foroushani A, Fallah Madvari A. Investigating the effect of increasing duration time of using the protective device on hearing loss among tile industry workers: Application of the BASNEF education model. J Health Saf Work 2017; 7 (4) :319-328
URL: http://jhsw.tums.ac.ir/article-1-5756-en.html
1- Professor, Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2- Instructor, Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran
3- Professor, Department of Health Education and Health Promotion, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
4- M.Sc., Student Research Committee, School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran , fallah134@yahoo.com
5- Professor, Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
6- B.Sc. of Department of Occupational Health Engineering, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
Abstract:   (5623 Views)

Introduction: The use of hearing protective devices (HPDs) is the last way for noise control. It is important to know the information about the duration time using these devices to ensure protetion effectiveness. The aim of this study was to investigate the effect of increasing duration time of the using of the devices on hearing loss in tile industry workers with application of the BASNEF education model.  

Material and Method: Task Base Method (TBM) and ISO9612(2009) standard methods through a noise dosimeter device were used to exmine workers’ noise exposure level when they didn’t used of HPDs. Actual performance of HPDs was determined by using the NIOSH standard before and after training intervention and measuring time of use and protection device type. Data were analyzed using SPSSVv19 and conducting t-test and ANCOVA statistical tests.   

Result: Before training intervention, the actual noise level for case workers was 89.76 dBA. On the contrary, this value was 84.04 dBA for after intervention, with a significant difference with control group (P<0.0001) using ANCOVA analysis. In control group, the actual level of noise has not changed because this group has not received any training.

Conclusion: The results revealed that, based on BASNEF education model, duration time of using hearing protection devices is effective on increasing their function and performance.

Full-Text [PDF 997 kb]   (4031 Downloads)    
Type of Study: Research |
Received: 2017/12/4 | Accepted: 2017/12/4 | Published: 2017/12/4

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb