<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health and Safety at Work</title>
<title_fa>بهداشت و ایمنی کار</title_fa>
<short_title>J Health Saf Work</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jhsw.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-807X</journal_id_issn>
<journal_id_issn_online>2383-2088</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و ساخت یک سنسور الکتروشیمیایی با ویژگی اندازه گیری دیازینون در پایش‌های محیطی و  بیولوژیکی</title_fa>
	<title>Development of a specific electrochemical sensor for occupational and environmental monitoring of diazinon </title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; با توجه به مصرف فراوان سموم آفت کش و اثرات مخرب آ&#8204;ن&#8204;ها روی انسان و محیط زیست، استفاده از روش&#8204;های دقیق و معتبر جهت شناسایی و اندازه گیری این سموم ضروری می&#8204;باشد. این مطالعه با هدف طراحی سنسوری با گزینش پذیری بالا برای پایش شغلی و محیطی دیازینون به روش الکتروشیمیایی در نمونه&#8204;های محیطی و بیولوژیکی انجام شد.&lt;br&gt;
&lt;br&gt;
&lt;strong&gt;روش کار&lt;/strong&gt;: نانولوله&#8204;های کربنی و پلیمر قالب مولوکولی (MIP) به عنوان اصلاح کننده در ساختار الکترود خمیر کربنی (سنسور) استفاده شدند. روش الکتروشیمیایی ولتامتری موج مربعی جهت تعیین مقدار به&#8204;کار رفت. پارامترهای تأثیر گذار بر پاسخ سنسور مانند pH استخراج، pH آنالیز، غلظت الکترولیت و شرایط دستگاهی مانند فرکانس و دامنه موج مربعی طی آزمایشاتی بهینه سازی شده، سپس پاسخ سنسور برای دیازینون ثبت گردید.&lt;br&gt;
&lt;br&gt;
&lt;strong&gt;یافته ها&lt;/strong&gt;: براساس نتایج، سنسور توانایی تشخیص گزینش پذیر دیازینون در نمونه&#8204;های محیطی و بیولوژیکی را داشت. بازه&amp;lrm;ی خطی برای منحنی کالیبراسیون 10-10&amp;times;5 تا 6-10&amp;times;1 مولار و حد تشخیـص روش10-10&amp;times;7/2 مولار محاسبه گردید. سایر ترکیبات موجود در ماتریکس نمونه اثر مداخله کننده ای بر پاسخ سنسور نداشتند. در نهایت سنسور برای تعیین مقدار دیازینون در نمونه&#8204;های ادرار، آب آشامیدنی و آب رودخانه بدون نیاز به مرحله آماده سازی خاص و پیچیده&#8204;ای استفاده شد.&lt;br&gt;
&lt;br&gt;
&lt;strong&gt;نتیجه گیری&lt;/strong&gt;: قابلیت کاربرد سنسورها در تعیین مقدار سموم می&#8204;تواند نوید بخش پایش&#8204;های سریع در محل آلودگی بوده و امکان انجام پایش را بدون مراحل آماده سازی خاص&amp;lrm; برای نمونه فراهم آورد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;Diazinon is commonly used for pest control in the agricultural fields because of its relatively low cost and high efficiency. Due to the increasing application of pesticides, reliable and accurate analytical methods are necessary for their monitoring. This work was aimed to design the high selective electrochemical sensor for determining of diazinon in biological and environmental samples. The composition of sensor was modified with multi-walls carbon nanotubes and a molecularly imprinted polymer (MIP). A diazinon MIP was synthesized and applied in the carbon paste electrode (CP). The prepared sensor was used to determine the concentration of analyte. Parameters affecting the sensor response, such as sample pH, electrolyte concentration and its pH, and the instrumental parameters of square wave voltammetry, were optimized in different levels to select the optimum conditions for analysis of diazinon. The MIP-CP electrode showed very high specificity for determining the analyte. The obtained linear range was 1&amp;times;10-6 to 5&amp;times;10-10 mol L-1. The detection limit was 2.7&amp;times;10-10 molL-1. This sensor was successfully used to determine the diazinon in environmental and biological real samples without special sample pretreatment before analysis.&lt;/p&gt;
</abstract>
	<keyword_fa>دیازینون, پلیمر قالب مولکولی, سنسور, ولتامتری, پایش بیولوژیکی و محیطی</keyword_fa>
	<keyword>Diazinon, Molecularly Imprinted Polymer, Sensor, Biological Monitoring</keyword>
	<start_page>9</start_page>
	<end_page>22</end_page>
	<web_url>http://jhsw.tums.ac.ir/browse.php?a_code=A-10-1-40&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Monireh </first_name>
	<middle_name></middle_name>
	<last_name>Khadem</last_name>
	<suffix></suffix>
	<first_name_fa>منیره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خادم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Farnoush </first_name>
	<middle_name></middle_name>
	<last_name>Faridbod</last_name>
	<suffix></suffix>
	<first_name_fa>فرنوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فریدبد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار،پردیس علوم، مرکز عالی الکتروشیمی، دانشگاه تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parviz </first_name>
	<middle_name></middle_name>
	<last_name>Norouzi</last_name>
	<suffix></suffix>
	<first_name_fa>پرویز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوروزی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran</affiliation>
	<affiliation_fa>استاد پردیس علوم، مرکز عالی الکتروشیمی، دانشگاه تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas Foroushani</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi Foroushani</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی فروشانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشیار دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Ganjali</last_name>
	<suffix></suffix>
	<first_name_fa>محمد رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گنجعلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran</affiliation>
	<affiliation_fa>استاد پردیس علوم، مرکز عالی الکتروشیمی، دانشگاه تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Jamaleddin </first_name>
	<middle_name></middle_name>
	<last_name>Shahtaheri</last_name>
	<suffix></suffix>
	<first_name_fa>سید جمال الدین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شاه طاهری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shahtaheri@sina.tums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Professor, Department of Occupational Health Engineering, School of Public Health, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استاد دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Rasoul </first_name>
	<middle_name></middle_name>
	<last_name>Yarahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>رسول</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاراحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Occupational Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشیار دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
