<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Health and Safety at Work</title>
<title_fa>بهداشت و ایمنی کار</title_fa>
<short_title>J Health Saf Work</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jhsw.tums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-807X</journal_id_issn>
<journal_id_issn_online>2383-2088</journal_id_issn_online>
<journal_id_pii>000</journal_id_pii>
<journal_id_doi>000</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>000</journal_id_sid>
<journal_id_nlai>000</journal_id_nlai>
<journal_id_science>000</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی عملکرد حرارتی سامانه‌های گرمایش تابشی سقفی و تاثیر آن بر سطح آسایش حرارتی کارگران در کارگاه‌های معمول صنعتی</title_fa>
	<title>Study of heating performance of radiant ceiling heating system and its impact on workers thermal comfort level of workers in typical industrial work shops</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;
&lt;strong&gt;مقدمه:&lt;/strong&gt; آسایش حرارتی در محیط کار و زندگی به عنوان یکی از مهم‌ترین دغدغه‌های انسان در نیم قرن گذشته بوده است. آسایش حرارتی شرایطی است که فرد از لحاظ ذهنی نسبت به شرایط جوی محیط خود احساس رضایت داشته باشد. یکی از سامانه‌های نسبتاً جدید برای ایجاد گرمایش در محیط‌های کاری، سامانه‌های گرمایش تابشی است. هدف از این پژوهش بررسی عملکرد حرارتی سامانه گرمایش تابشی سقفی و تاثیر آن بر سطح آسایش حرارتی کارگران می‌باشد.
&lt;/p&gt;&lt;p&gt;&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;روش کار:&lt;/strong&gt; درمطالعه توصیفی تحلیلی حاضر، سامانه‌های گرمایش تابشی طراحی شده در دو کارگاه تعمیرات و نگهداری مرکز بهره‌برداری خطوط لوله گاز همدان مورد ارزیابی قرار گرفت. ابتدا پارامترهای محیطی تاثیرگذار بر آسایش حرارتی در هر دو کارگاه‌، قبل و بعد از روشن شدن سیستم گرمایش تابشی سقفی، اندازه‌گیری و بر اساس آنها شاخص خنک کنندگی باد و  شاخص‌های آسایش حرارتی، میانگین رای پیش بینی شده (PMV) و درصد افراد ناراضی (PPD)  محاسبه گردید. با استفاده از پرسشنامه  توزیع شده در بین 22 نفر از کارگران شاغل در کارگاه‌های مورد مطالعه، شاخص PMV و PPD  بر اساس احساس ذهنی کارگران از شرایط آسایش حرارتی تعیین گردید.
&lt;/p&gt;&lt;p&gt;&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt; نتایج نشان داد سامانه گرمایش تابشی سقفی در کارگاه شماره یک، شاخص خنک‌کنندگی باد را به میزان Kcal/m2.h 3/42 کاهش داده است که این مقدار تاثیرقابل ملاحظه‌ای در تغییر شرایط آسایش حرارتی محیط نداشته است. در کارگاه شماره دو، شاخص خنک‌کنندگی باد به میزان Kcal/m2.h 3/109 کاهش یافته است که در این وضعیت شرایط آسایش حرارتی از احساس محیط سرد به محیط مطلوب تغییر یافته است. شاخص PMV در کارگاه شماره یک بعد از روشن شدن سامانه نسبت به قبل 37/0 افزایش داشته است که این مقدار برابر افزایش 24/17 درصد رضایت افراد بود، در حالی که در کارگاه شماره دو، تغییر افزایشی شاخص PMV قبل و بعد از روشن شدن سامانه 98/0 بود که این مقدار برابر افزایش قابل ملاحظه 6/31 درصد رضایت افراد بود. بر این اساس درصد رضایت در کارگاه شماره دو نسبت به کارگاه شماره یک به میزان 3/14 بیشتر بوده است.
&lt;/p&gt;&lt;p&gt;&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; با توجه به حجم بزرگ این نوع کارگاه‌های صنعتی، گرمایش موثر کارگاه‌ از طریق مکانیسم‌های همرفتی بسیار مشکل و پرهزینه می‌باشد. نتایج تایید نمود در صورتی که سامانه‌های گرمایش تابشی در کارگاه‌های صنعتی بر اساس اصول علمی طراحی و به‌کار گرفته شوند می‌توانند در بهبود آسایش حرارتی به دلیل گرمایش سطوح مجاور از طریق تابش و کاهش در مصرف سوخت و هزینه بسیار اثربخش باشند.
&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;
&lt;strong&gt;Introduction:&lt;/strong&gt; Introduction: Thermal comforts are one of the most human concerns in working as was as living environments in the past half century. Thermal comfort is the condition in which people are satisfied with the thermal environment, mentally. One of the new heating system employed in individual units is radiant heating system .The purpose of this study was to investigate the performance of radiant ceiling heating system and its impact on thermal comfort of workers.&lt;/p&gt;&lt;p&gt;&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;
&lt;strong&gt;Material and Method:&lt;/strong&gt;  In the present analytical-descriptive study, the designed radiant heating systems were investigated in two repair and maintenance units, in Hamadan gas pipeline operation center. Firstly, the environment parameters, witch impact thermal comfort, were measured before and after using radiant heating system, in both understudy units. Then, wind chill index, thermal comfort indices, PMV and PPD were calculated. In addition, PPD and PMV were determined, based on workers subjective feeling by a questionnaire distributed among 22 workers.&lt;/p&gt;&lt;p&gt;
&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; According to the results, the radiant heating system in unit 1, has reduced the wind chill index by 42.3 Kcal/ m2.h, witch is not considered to be significant. In unit 2, wind chill index has been decreased by 109.3 Kcal/ m2.h, witch mean that thermal comfort has been changed from cold to an optimum environment. PMV n unit 1 went up by 37% after turning the system on, witch is equal to 17.24% increase in workers satisfaction. However, in unit 2, the workers satisfaction was 14.3% higher in comparison with unit 1.
&lt;/p&gt;&lt;p&gt;&lt;font color=&quot;#ffffff&quot;&gt;.&lt;/font&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Due to large space of these industrial units, producing appropriate heating by convection mechanism is too difficult and expensive. The results confirmed that if radiant heating system applied based on scientific design principles they could be effective in promotion of thermal comfort due to heating surrounding surface by radiant and also reducing fuel consumption.

&lt;/p&gt;</abstract>
	<keyword_fa>سامانه گرمایش تابشی، آسایش حرارتی، شاخص PMV، شاخص PPD</keyword_fa>
	<keyword>Radiant heating system, Thermal comfort, PMV index, PPD index</keyword>
	<start_page>47</start_page>
	<end_page>58</end_page>
	<web_url>http://jhsw.tums.ac.ir/browse.php?a_code=A-10-25-63&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M. </first_name>
	<middle_name></middle_name>
	<last_name>Aliabadi</last_name>
	<suffix></suffix>
	<first_name_fa>محسن </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی‌آبادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Hygiene, Faculty of public health, Hamadan University of Medical Sciences,</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه‎ای، دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>G. </first_name>
	<middle_name></middle_name>
	<last_name>Hesam</last_name>
	<suffix></suffix>
	<first_name_fa>قاسم </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسام</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ghasem_hesam@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Hygiene, Faculty of public health, Hamadan University of Medical Sciences,</affiliation>
	<affiliation_fa>مهندسی بهداشت حرفه‎ای، دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>R. </first_name>
	<middle_name></middle_name>
	<last_name>Rahimpoor</last_name>
	<suffix></suffix>
	<first_name_fa>رزاقپور</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> رحیم پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Hygiene, Faculty of public health, Hamadan University of Medical Sciences,</affiliation>
	<affiliation_fa>مهندسی بهداشت حرفه‎ای، دانشکده بهداشت، دانشگاه علوم پزشکی و خدمات بهداشتی درمانی همدان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
