Volume 3, Number 4 (2-2014)                   JHSW 2014, 3(4): 1-10 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jahangiri M, Neghab M, Rostami R, Aghabeigi M, Kahdemain V, Zare Derisi F. Evaluating Bioaerosol Emissions form in different parts of a Sanitary Wastewater Treatment Plant. JHSW. 2014; 3 (4) :1-10
URL: http://jhsw.tums.ac.ir/article-1-5096-en.html

1- Assistant Professor Department of Occupational Health, School of Public Health, Shiraz University of
2- 2Professor Department of Occupational Health, School of Public Health, Shiraz University of Medical , neghabm@sums.ac.ir
3- MSc of Occupational Health, Student Research Committee, Shiraz University of Medical Sciences
4- MSc of Occupational Health, HSE Department, National Petrochemical Company, Iran
5- BSc of Occupational Health, Student Research Committee, Shiraz University of Medical Sciences
Abstract:   (11040 Views)

Introduction: Bioaeroslos released from wastewater treatment plants may contain pathogens existing in the sewage which could endanger the health of workers. The aim of this study was to evaluate the status of bioaerosol emissions form in a sanitary wastewater treatment plant.

.

Material and Method: This cross-sectional study was carried out in different units of a sanitary wastewater treatment plant. For this purpose, air samples were collected on blood agar and dextro agar in an Andersen single-stage sampler with flow of 28.3 lit/min for 10 minutes. Collected samples were shipped to the lab immediately and incubated for 48 hours. Then, incubated samples were counted for colonies concentration.

.

Result: Based on the result of this study, the mean density of bacterial and fungal bioaerosols in all wastewater treatment plants were 412.86±23.30 and 53.72±23.99 CFU/m3, respectively. Microbial contamination of the air within a kilometer away from the site (control areas) was 17 times less than its average density.

.

Conclusion: Wastewater treatment processes can contaminate the air surrounding the plant, particularly with bacteria bioaerosols. Therefore, it is necessary to control the emissions and protect the health of workers against risks arising from exposure to bioaerosols.

Full-Text [PDF 336 kb]   (1407 Downloads)    
Type of Study: Research | Subject: Special
Received: 2013/08/25 | Accepted: 2013/11/11 | Published: 2014/02/22

Add your comments about this article : Your username or email:
Write the security code in the box

Send email to the article author


© 2017 All Rights Reserved | Health and Safety at Work

Designed & Developed by : Yektaweb